Ny definition af performance og effektivitet indenfor Q-Switched Nd:YAG laser
TRI-BEAM er det eneste rigtige valg, hvis du vil opnå det bedste resultat ved brug af Q-Switched Nd:YAG Teknologi.
Fotoakustiske teknikker
Rich-PTP(Photoacoustic Toning Pulse) er en unik teknologi som er i TRI-BEAM og som medfører den bedste effektivitet i forhold til andre Q-switched Nd:YAG maskiner. Som direkte konsekvens heraf oplever vi en meget større kundetilfredshed med et meget bedre æstetisk resultat end man kan opnå med andre maskiner.
Fraktionel Håndtag

Den nyeste Nd:YAG laser teknologi.
Fraktionel laserhudbehandling:
- Høj behandlingseffektivitet ved dyb laserpenetrering
- Epidemis sparing during High fluence treatment
- Minimize PIH, Hypo-pigmentation and side effects
- 81 prikker indenfor 5 x 5 mm.
Gen Technique by using Quasi-Lon Pulse
Quasi-Long Pulse 1,065nm Gen Technique is functional combination of theral lifting and toning by using fundamental of selective photothermolysis. Gen Technique is not only good for pigmentaion lesions, but also useful treatment for general skin rejuvenation of reducing large pores and skin lifting.
Gen Technique
To express meaning of the new genesis of skin rejuventaion for skin re-born, root “Gen” is used which does have meanings of birth, cause, and race.
It is also the target objective of TRI-BEAM treatment technique.
Gen Technique for photorejuvenation is the new paradigm of laser technology that brings the better efficacy for large pore, peeling and lifting by destroying deep pigmentation and regenerating collagen.
Lifting and toning by using fundamental of selective photothermolysis. Gen Technique is not only good for pigmentation lesions, but also useful treatment for general skin rejuvenation of reducing large pores and skin lifting.
Tri-Beam removes:
2 Pulse / 20Hz/, Powerful Rich-PTP Toning
Fast and effective treatment
2 pulse of TRI-BEAM delivers more efficacy and minimizes the adverse effects for Melasma tretment.
20Hz of 2 pulse energy makes faster and safer treatment than current laser toning devices.
Prevention of reoccurrence of melasma
The True Flat-Top mode delivers stable 2 pulse of 20Hz. It prevents to reoccur melasma and reduces adverse effects such as Post Inflammatory Hyper-pigmentation (PIH).
Efficacies expected on skin tightening, reducing pore, and skin rejuvenation
2 pulse of 20Hz stimulates fibroblasts and gives effective anti-aging results including skin tightening, pore reducing, peeling, lifting and skin rejuvenation.

Laser Parameter
Laser Medium
Nd:YAG (Q-Switched)
Operating Parameters
Q-Switched and Quasi-Long Pulse
Wave Length
1064/532nm
Energy at end of Handpiece
Q-Switched
PTP mode
Top Hat mode
Gaussion mode
1064 nm
1064 nm
532 nm
1064 nm
1.6 Joule
1.2 Joule
450 mJoule
1.5 Joule
Quasi-Long Pulse
1064 nm
3.5 Joule
Pulse Width
Q-Switched
5 – 10 ns
Quasi-Long Pulse
300 µs
Repetition Rate
Single shot, 1 – 20 Hz (pulses per second)
Beam Profile
True Flat-Top
Energy Calibration
Internal
Spot Sizes
Zoom Handpiece
1064 nm
2 mm ∼ 10 mm
(Auto Sensing)
532 nm
2 mm ∼ 10 mm
Collimate Handpiece
7 mm
Fractional Handpiece
5 mm x 5 mm (81 spots)
Physical Parameters
Electrical Power
220 V, Single Phase, 50/60 Hz, 20 Amps at 220V AC
Weight
110 kg
Dimensions
954 mm (H) x 440 mm (W) x 950mm (L) without articulated arm
Beam Delivery
Articulated arm with up to 240 cm reach, 7-joint, 360° rotation
Cooling
Closed cycle water to air heat exchanger